Skip to content

Specific portlets

Specific portlets

Specific portlets that are used for models of three device manufacturers:

  • Engine event behavior for ATrack.
  • Guard mode for Yatut.
  • Harsh behavior for Suntech.

engine_control_atrack

Special settings to set the engine event behavior for ATrack.

{
    "power_voltage_high_level": 13800,
    "on_duration_seconds": 120,
    "power_voltage_low_level": 12800,
    "off_duration_seconds": 300
}
  • power_voltage_high_level - int. Voltage in 0.001 volts for detecting engine ON state. Min=0, max=30000, default=13800 mV.
  • on_duration_seconds - int. Duration in seconds that must elapse before the engine state change accepted. Min=0, max=600, default=1 second.
  • power_voltage_low_level - int. Voltage in 0.001 volts for detecting engine OFF state. Min=0, max=30000, default=12800 mV.
  • off_duration_seconds - duration in seconds that must elapse before the engine state change accepted. Min=0, max=600, default=5 seconds.

guard_mode_yatut

Guard special settings for "Я ТУТ ПОИСК".

{
    "motion_sensor_mode": "double_period",
    "motion_sensor_first_period": "23:00-07:00",
    "motion_sensor_second_period": "10:00-17:00",
    "motion_sensor_amplitude": 10,
    "motion_sensor_duration": 30,
    "motion_sensor_ignore_time": 50,
    "motion_sensor_double_check": false,
    "perimeter_mode": "once_triggering",
    "perimeter_diameter": 1
}
  • motion_sensor_mode - enum. Can be "off" | "permanent" | "single_period" | "double_period". Default="off".
  • motion_sensor_first_period - string time. Format=HH:mm-HH:mm, default="23:00-07:00" Required for motion_sensor_mode in single_period/double_period.
  • motion_sensor_second_period - string time. Format=HH:mm-HH:mm, default="10:00-17:00" Required for motion_sensor_mode in double_period.
  • motion_sensor_amplitude - int. Min=1, max=255, default=5 Required for motion_sensor_mode != off.
  • motion_sensor_duration - int. Min=1, max=255, default=5 seconds. Required for motion_sensor_mode != off.
  • motion_sensor_ignore_time - int. Min=5, max=99, default=5 minutes. Required for motion_sensor_mode != off.
  • motion_sensor_double_check - boolean. Default=false. Required for motion_sensor_mode != off.
  • perimeter_mode - enum. Can be "off" | "once_triggering" | "permanent" | "point_displacement". Default="off".
  • perimeter_diameter - int. Min=1, max=999, default=1 kilometer. Required for perimeter_mode != off.

harsh_behavior_suntech

Harsh driving settings for Suntech.

{
    "mode": "enable",
    "max_acceleration_force": 1.5,
    "max_braking_force": 0.05,
    "max_cornering_force": 3,
    "type": "harsh_behavior_suntech"
}
  • mode - string. Can be "enable" | "disable".
  • max_acceleration_force - double. Can be 0.05 – 3.0 g.
  • max_braking_force - double. Can be 0.05 – 3.0 g.
  • max_cornering_force - double. Can be 0.05 – 3.0 g.

Last update: October 31, 2021